Stability indicating assay method of sirolimus using HPLC and separation of acid degradant by HPTLC

By: Jadhav, S.
Contributor(s): Pisal, P | Mahajan, M.
Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2018Edition: Vol. 55 (04) April.Description: 48-55.Subject(s): PHARMACEUTICS | RP+HPLC | Stress degradationOnline resources: Click here In: Indian drugsSummary: A stability indicating RP-HPLC method has been developed and subsequently validated for Sirolimus. The proposed RP-HPLC method utilizes Phenomenex, C18, 3 μm, 4 mm x 150 mm column, mobile phase consisting of acetonitrile and water (65:35 V/V) and UV detection at 277 nm using a photodiode array detector in the stressed sample chromatograms. Crushed sirolimus tablets were exposed to thermal, photolytic, aqueous and oxidation stress conditions and stressed samples were analysed by the proposed method. Peak homogeneity data of the drug peaks were obtained using photodiode array detector. The stressed sample chromatograms demonstrated the specificity of the method for their estimation in presence of degradants. 99.66% degradation was observed in acid degradation study. on the other hand, no degradation was observed in aqueous condition. The given method was linear over a range of 0.1566 mg/mL to 0.4699 mg/mL. The mean recovery was found to be 99.23%. Acid degradant was separated by HPTLC and spectroscopic analysis was performed for the same.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2018045
Total holds: 0

A stability indicating RP-HPLC method has been developed and subsequently validated for Sirolimus. The proposed RP-HPLC method utilizes Phenomenex, C18, 3 μm, 4 mm x 150 mm column, mobile phase consisting of acetonitrile and water (65:35 V/V) and UV detection at 277 nm using a photodiode array detector in the stressed sample chromatograms. Crushed sirolimus tablets were exposed to thermal, photolytic, aqueous and oxidation stress conditions and stressed samples were analysed by the proposed method. Peak homogeneity data of the drug peaks were obtained using photodiode array detector. The stressed sample chromatograms demonstrated the specificity of the method for their estimation in presence of degradants. 99.66% degradation was observed in acid degradation study. on the other hand, no degradation was observed in aqueous condition. The given method was linear over a range of 0.1566 mg/mL to 0.4699 mg/mL. The mean recovery was found to be 99.23%. Acid degradant was separated by HPTLC and spectroscopic analysis was performed for the same.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha